E00:00000, Platinum Resistance Flame Sensor (Combustion Sensor)
E00:00000, Platinum Resistance Flame Sensor (Combustion Sensor)
Function: Determine whether the combustion is normal
Detection Standard:
1. The appearance of the adhesive injection part is normal, with no melting or detachment;
2. Measuring resistance with a multimeter, the resistance increases as the ambient temperature rises. Reference range:
0℃-999.85-1000.15kΩ;
10℃-1038.855-1039.195kΩ
20℃-1077.745-1078.125kΩ;
Fault Phenomenon:
1. Open circuit (fault code E00); 2. Short circuit (fault code E04);